Application areas
Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm.
Electromagnetic flowmeter. Modular design in compact and separate version. Readings are independent of density, viscosity, temperature and liquid pressure. Without moving elements and with a low pressure drop. Suitable for liquids with solids. High chemical resistance. Can be installed in any position, provided that the pipe is always full (in vertical pipes upwards flow is recommended). Low power consumption.
| Output 4-20 mA /0 … 1000 Hz. Totalizer Flow indication Batching | |
| Measuring range | 10 l/h … 7000 m3/h H2O |
| Accuracy | =±0,5% f.e. |
| Connections | DN3 … DN500, others on request DIN o ANSI flanges (FLOMID-2FX, FLOMID-4FX) Between flanges DIN or ANSI (FLOMID-0FX) Sanitary connection Others on request |
| Materials | Body: EN 1.4404 (AISI 316L) Liner: PP, PVDF, ebonite y PTFE Electrode: Hastelloy C, EN 1.4404, Zr, Ti y Tantalum |
| Options | High pressure design on request (only for flange connection) Other flange standard on request HART ™ protocol on request |